infrastructure:co2_sensors [2024-02-07 09:38 UTC] aveinfrastructure:co2_sensors [2024-07-06 22:50 UTC] (current) – Use esphome domain with valid cert. june
Line 36: Line 36:
 The sensors are connected to an ESP8266 with an 8mm PL9823 RGB LED (which uses WS2812B protocol, except it's RGB, not GRB). They're wired up on a (very annoyingly: double-sided) perfboard. There's a logic level shifter for the data pin of the RGB LED, circuit diagrams will be posted at some point. The sensors are connected to an ESP8266 with an 8mm PL9823 RGB LED (which uses WS2812B protocol, except it's RGB, not GRB). They're wired up on a (very annoyingly: double-sided) perfboard. There's a logic level shifter for the data pin of the RGB LED, circuit diagrams will be posted at some point.
  
-The ESP8266 runs esphome, the configs are available on [[https://esphome.z9.ccchh.net/|our esphome instance]]. For some reason it cannot connect to the devices, so you'll still want to flash them through your computer or something (for now I'm using it as just a config storage).+The ESP8266 runs esphome, the configs are available on [[https://esphome.ccchh.net/|our esphome instance]]. For some reason it cannot connect to the devices, so you'll still want to flash them through your computer or something (for now I'm using it as just a config storage).
  
 For sensor choice justification see [[https://queer.party/@ao/111779978098588711|this fedi post]], TL;DR: NDIR sensors are the only cheap, small and good way to get CO2 data currently, and many other cheaper options require a lot more maintenance due to their calibration logic being worse. For sensor choice justification see [[https://queer.party/@ao/111779978098588711|this fedi post]], TL;DR: NDIR sensors are the only cheap, small and good way to get CO2 data currently, and many other cheaper options require a lot more maintenance due to their calibration logic being worse.
infrastructure/co2_sensors.txt · Last modified: by june

Except where otherwise noted, content on this wiki is licensed under the following license: CC0 1.0 Universal
CC0 1.0 Universal Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki